Document Type : Review Article

Author

Abstract

In this paper, a new zero voltage switching isolated buck-boost DC-DC converter with active clamp circuit is proposed. The active clamp circuit in this converter not only absorbs voltage spikes across the main switch but also provides soft switching conditions for all switches. All switches are PWM controlled which simplifies the control implementation. One of the main advantages of this converter is the that it operating can operate at high power levels while soft switching conditions exist in both buck and boost modes of converter operation. Since this converter can operate over a wide input voltage range, it can be employed in power factor correction. The experimental results obtained from a 150W prototype circuit operating at 100KHz are presented to confirm the integrity of the proposed circuit.

Keywords

[1] Wei S. and Lehman B.; “Current-Fed Dual-Bridge DC–DC Converter” IEEE Trans on Power Electronics, Vol. 22, pp.461 – 469, (2007)
[2] Hanju Ch., Jungwan Ch. and Enjeti P.N.; “A Three-Phase Current-Fed DC/DC Converter with Active Clamp for Low-DC Renewable Energy Sources”, IEEE Trans on Power Electronics, Vol.23, pp.2784 – 2793, (2008)
[3] Andersen R.L. and Barbi I.; “A Three-Phase Current-Fed Push–Pull DC–DC Converter”, IEEE Trans Power Electronics, Vol. 24, No. 2, pp.358 – 368, (2009)
[4] Wai R.J. and Duan R.Y.; “High-Efficiency Dc/Dc Converter with High Voltage Gain” IEEE Electr. Power Appl., Vol. 152, pp. 793 - 802, (2005)
[5] Barbosa P.M and Barbi. I; A Single-Switch Flyback-Current-Fed DC-DC Converter, IEEE Transactions on Power Electronics, Vol 13, pp466 – 475, (May 1998)
[6] Canesin C.A., Barbi. I.; “Novel Zero Current Switching PWM Converters”, IEEE Transaction on Industrial Electronics, Vol. 44, No. 3, pp 327-381, (Jun 1997)
[7] Hua G. and Lee F.C.; “Soft Switching Techniques in PWM Converters”, IEEE Transaction on Industrial Electronics, Vol. 4, No. 6, pp 595-603, (December 1997)
[8] B.Choi, W. Lim, S.Bang and S. Choi.; “Small Signal Analysis and Control Design of Asymmetrical Half-Bridge Dc-Dc Converters”, IEEE Transaction on Industrial Electronics, Vol. 53, No. 2, pp. 511 - 520, (April 2006)
[9] Han S.K, Yoon H.K, Moon G.W, Youn M.J, Kim Y.H and Lee K.H.; “A New Active Clamping Zero-Voltage Switching Pwm Current-Fed Half-Bridge Converter”, IEEE Transactions on Power Electronics, Vol. 20, , pp.1271 – 1279, (November 2005)
[10] Lo Y.K, Kao T.S and Lin J.Y.; “Analysis and Design of an Interleaved Active-Clamping Forward Converter”, IEEE Transactions on Industrial Electronics, Vol. 54, pp.2323 – 2332, (August 2007)
[11] Wu T.F, Lai Y.S, Hung J.C and Chen Y.M.; “Boost Converter with Coupled Inductors and Buck–Boost Type of Active Clamp”, Vol. 55, pp.154 - 162, (January 2008)
[12] Fuller J.F., Fuchs E.F. and Roesler K. J.; “Influence of Harmonics on Power Distribution System Protection”, IEEE Trans. Power Delivery, Vol. 3, pp. 549 - 557, (Apr. 1988)