Document Type : Review Article

Authors

1 M.A in Electrical Engineering, Shahid Chamran University of Ahvaz, Ahvaz

2 Assistant Professor of Electrical Engineering, Shahid Chamran University of Ahvaz, Ahvaz

3 Associate Professor of Electrical Engineering, Shahid Chamran University of Ahvaz, Ahvaz

Abstract

In this paper, the influence on the voltage compensation type, active superconducting fault current limiter (ASFCL) is investigated under symmetrical and asymmetrical fault conditions. ASFCL is consisting of three air-core superconducting transformers and a three-phase voltage source converter. In the normal (no fault) state, the flux in air core is compensated to zero, so the ASFCL has no influence on the main circuit. In the case of short circuit, by controlling the amplitude and phase angle of the second winding’s current, the limiting impedance which is in series with the AC main circuit can be regulated, and the fault current will be limited to a certain level. Control strategies consist of fault detection and PWM converter operation is designed. To simplify the design of controllers the mathematical equations can be expressed in synchronous rotating d-q frame. Furthermore, under the condition that the active SFCL is placed behind the relay element, its current-limiting impedance will be added into the measured impedance between the relay and the fault points. As a result, in order to prevent the refused operation of the relay, According to the two different operation modes of the active SFCL, in this paper present the corresponding two modified formulas. Using MATLAB SIMULINK, model of the three phase AC system with ASFCL is created and control strategies test, fault current limiting test, and distance relay operation is investigated.

Keywords

[1] Jin Wang, Libing Zhou, Jing Shi, and Yuejing Tang “Experimental Investigation of an Active Superconducting Current Controller”, IEEE Transactions On Applied Superconductivity, VOL. 21, NO. 3, JUNE 2011
[2] Meng Song, Yuejin Tang, Yusheng Zhou, Li Ren, Lei Chen, and Shijie Cheng, “Electromagnetic Characteristics Analysis of Air Core Transformer Used in Voltage Compensation Type Active SFCL”, IEEE Transactions On Applied Superconductivity, VOL. 20, NO. 3, JUNE 2010
[3] Lei Chen , Yuejin Tang, Jing Shi, Zhi Li, Li Ren, Shijie Cheng “Control strategy for three-phase four-wire PWM converter of integrated voltage compensation type active SFCL”, Physica C 470, (2010) 231–235.
[4] L. Chen , Y.J. Tang J. Shi , L. Rena, M. Song , S.J. Cheng , Y. Hu, X.S. Chen “Effects of a voltage compensation type active superconducting fault current limiter on distance relay protection”, Physica C 470 (2010) 1662–166.
[5] M. Song , Y. Tang , J. Li , Y. Zhou , L. Chen , L. Ren “Thermal analysis of HTS air-core transformer used in voltage compensation type active SFCL”, Volume 470, Issue 20, 1 November 2010, Pages 1657–1661
[6] Shateri, H., Jamali, S. “Measured impedance by distance relay for inter phase faults in presence of resistive Fault Current Limiter”, Power System Technology (POWERCON), International Conference, 2010.
[7] Shateri, H., Jamali, S. “Comparing measured impedance by distance relay in presence of resistive and inductive Fault Current Limiters”, PowerTech, IEEE Bucharest, 2009.
[8] L. Chen, Y. J. Tang, J. Shi, N. Chen, M. Song, S. J. Cheng, Y. Hu, and X. S. Chen, “Influence of a voltage compensation type active superconducting fault current limiter on the transient stability of power system,” Phys. C, vol. 469, no. 15–20, pp. 1760–1764, October 2009.
[9] L. Ye, L. Lin, and K. P. Juengst, “Application studies of superconducting fault current limiters in electric power system”, IEEE Trans. Applied Superconductivity, vol. 18, no. 2, pp. 624–627, 2008.
[10] B. W. Lee, J. Sim, K. B. Park, and I. S. Oh, “Practical application issue of superconducting fault current limiters for electric power system”, IEEE Trans. Applied Superconductivity, vol. 18, no. 2, pp. 620–623, 2008.
[11] Geethalakshmi, B.; Dananjayan, P. “Comparing measured impedance by distance relay in presence of resistive and inductive Fault Current Limiters”, Power Electronics and Drive Systems, 2007. PEDS '07. 7th International Conference.